MATERIAL SAFETY DATA SHEET
SECTION 1
IDENTITY: GENTELL LO PRO FOAM™ PLUS DRESSING Polyurethane membrane coated with acrylic-based
medical adhesive incorporating a foam absorbent component.
MANUFACTURER’S NAME: Gentell, 3600 Boundbrook Ave., Trevose, PA 19053
EMERGENCY & INFORMATION
PHONE: 800-840-9041
DATE PREPARED: 6-10-2004
HAZARD RATING (NFPA DESIGNATION)=0
4=EXTREME 3=HIGH 2=MODERATE 1=SLIGHT 0=INSIGNIFICANT
FIRE=0 HEALTH=0 REACTIVITY=0
SECTION 2
HAZARDOUS INGREDIENTS/IDENTITY
INFORMATION
COMPOUND: None
SECTION 3
PHYSICAL/CHEMICAL
CHARACTERISTICS
BOILING
POINT (DEGREES F): N/A
SOLUBILITY
IN WATER: N/A
SP
GRAVITY (WATER =1): Not available
%
VOLATILE BY VOLUME @ 110ºC: Not Available
APPEARANCE
AND ODOR: fleshtone, odorless laminate pad
SECTION 4
FIRE & EXPLOSION HAZARD DATA
FLASH
POINT: N/A
FIRE
EXTINGUISHING MEDIA: Water, dry
chemical or foam
SPECIAL
FIRE FIGHTING PROCEDURES: Use
self-contained breathing apparatus and protective clothing.
UNUSUAL
FIRE AND EXPLOSIVE HAZARDS: N/A
SECTION 5
HEALTH HAZARD DATA
Has the
product or any unreacted ingredient been listed as a carcinogen or potential
carcinogen by the National Toxicology Program Annual Report on Carcinogens or
the International Agency for Research on Cancer?
No: N/A
Yes:
Ingredients:
Has
this product or any unreacted ingredient (1%) been listed as toxic and
hazardous substance according to 29CfR 1910.1000 Subpart Z?
No: N/A
Yes:
Ingredients:
EFFECTS OF OVEREXPOSURE:
EYE
& SKIN CONTACT: May cause moderate
irritation in eyes
INHALATION: N/A
ADDITIONAL INFORMATION:
Lo Pro Foam™ Plus dressing has passed testing in accordance with BENESISO
10993-1 biological evaluation of medical devices Part 1: Guidance on selection
of tests for Skin Irritation, Sensitization and Cytotoxicity. This product
is not considered to pose a significant hazard when used as intended and
under normal conditions.
EMERGENCY & FIRST AID
PROCEDURES:
EYE
CONTACT: May cause irritation in individuals with sensitivity to adhesives
SKIN
CONTACT: This product is intended for dkin contact, may cause irritation in individuals
with sensitivity to adhesives
INHALATION
OVEREXPOSURE: Occasional idiosyncratic dermatological reactions.
EXCESSIVE
INGESTION: Not considered toxic, may be harmful if ingested in large quantities,
therefore,consult physician
SECTION 6
REACTIVITY DATA
STABILITY: Stable
CONITIONS & MATERIALS TO AVOID: Avoid overheating and freezing. Store at 15ºC - 25ºC. Avoid direct
sunlight and moisture.
HAZARDOUS
POLYMERIZATION: None known
SECTION 7
SPILL, LEAK, AND WASTE DISPOSAL
PROCEDURES
SPILL: N/A
LEAK: N/A
WASTE
DISPOSAL: In accordance with all local,
state and federal regulations
WASTE DISPOSAL METHODS
Dispose
of in accordance with all local, state and federal regulations.
SECTION 8
SPECIAL PROTECTION INFORMATION
Not
Applicable
SECTION 9
SPECIAL PRECAUTIONS
No
special precautions necessary.
SECTION 10
ADDITIONAL INFORMATION
Not
Applicable
Notice to Reader
All substances may pose unknown
hazards and should be used with care.
This Material Safety Data Sheet applies only to the material as packaged
and for its intended use. If this
product is combined with other materials, deteriorates, or becomes
contaminated, it may pose hazards not mentioned above. It shall be the user's responsibility to
develop proper methods of handling and safety based on the actual conditions of
use. While the information contained in
this MSDS is based on technical data judged to be reliable, Gentell assumes no
responsibility for the completeness or accuracy of the information contained
herein.
Gentell Lo Pro Foam™ Plus Dressing V. 1.0
|